Store

LSA-TL

Login to see prices

Description

►Overview:

  • For application in dry or damp rooms with or without condensation
  • Temperature range storage/operation……………………..-40 to +80°C (-40 to 176°F)

►Downloads:

 

 

Additional information

Features and Benefits

►Mechanical values for plastic insulated copper conductors:
● Wire diameter for connection with one or two solid wires (same diameter and same
type)………………………………………….…0.40 to 0.65mm_ AWG 26 to 22
● Overall diameter (insulation PVC and PE)…………………………..0.70 to 1.10mm
● Repeatability of the wire connecting ……………….200x (With strands or solid wires 0.4 to 0.65mm)
►Electrical values:
The electrical values were collected after 4-day storage in a constant climate environment at
40°C (104°F) and 93% relative humidity
● Insulation resistance at 500V….…………………………………………>5 x 104MΩ
● Dielectric strength………………………………………………………………..2kVrms
● Impulse strength (waveform 1.2/50µs)……………………………………………….3.6kV
● Permitted current carrying capacity of the LSAGTL contact…………5kA (waveform 8/20µs)
● Contact resistance (wire connection)……………..……………………Typical 1.0mΩ
● Guaranteed…………………………………………………….………………….≤2.5mΩ
● Total resistance disconnection contact incl………………………………….≤10.0mΩ
►Transmission technical values:

The LSA-TL-P modules are suitable for the following communication services:
● xDSL and other analogue and digital telecommunication services
● Ethernet (10BaseT) with 10MBit/s
● Token Ring with 4 or 16MBit/s
● TPDDI with 100Mbit/s

Applications

● Fully tool-less disconnection module with LSA-contacts (45° angle) for connecting plasticinsulated
copper conductors
● The tool-less design allows wire termination without special insertion tool
● Separate test ports to test both ways
● Silicone Gel encapsulation to provide excellent environmental protection
● Insulation displacement connection according to IEC 60352-4 and DIN-41-611-6-C-EL-CL

►Technical Specifications: